Справочник Пользователя для 3com SuperStack II

Скачать
Страница из 212
38
C
HAPTER
 3: I
NSTALLING
 
THE
 H
ARDWARE
Attaching a 
Redundant Power 
System
You can attach your SuperStack II bridge/router to a SuperStack II 
Redundant Power System (RPS).
For full power supply redundancy, attach one end of the RPS cable to the 
rear panel on the bridge/router and the other end to the RPS. Then attach 
one end of the power cord to the rear panel on the bridge/router and the 
other end to a power outlet. 
In this configuration, the internal supply provides power. If the internal 
supply fails or is switched off, or if there is a power failure, the RPS is 
activated and the bridge/router reboots. 
To reset a bridge/router in this configuration, turn the power off, wait 5 
seconds and turn it back on. The bridge/router switches to the RPS, then 
switches back to the internal supply to reboot.
CAUTION: For system susceptibility protection, always leave the AC cord 
attached to the bridge/router and to a power outlet.
Internal power supply failure is rare. If it occurs, the power switch on your 
bridge/router will not operate. To reboot, unplug the RPS cable and then 
plug it back in. Replace your bridge/router with another bridge/router 
that has a functioning internal power supply as soon as possible. Contact 
your 3Com representative to replace your bridge/router.
Wall outlet
RPS cable
Power cable
Power cable
SuperStack II bridge/router
SuperStack II Redundant Power System