4
I
NSTALLING
 
OR
 R
EMOVING
 
AN
 
I
NTERFACE
 M
ODULE
This chapter describes how to install or remove interface modules in 
SuperStack II NETBuilder SI bridge/routers.
The following table lists each model number and the interface module it 
contains. 
You can change any model 4xx bridge/router to another model 4xx, or 
any model 5xx bridge/router to another model 5xx bridge/router by 
installing, removing, or replacing the interface module.
Removing the 
Cover
To remove the cover, follow these steps:
Remove the power cord and all cables from the chassis.
If the bridge/router is mounted with brackets, unmount it and remove the 
brackets.
Remove the two screws from the back of the chassis.
Model
Module Installed
43x/53x
ISDN S/T port with no interface module
44x/54x
ISDN U interface module
45x/55x
56/64 Kbps CSU/DSU module
46x/56x
T1/FT1 CSU/DSU module
Remove screws