Power Supply Requirements, Specifications, and Twist Lock Options
A-2 Specifications and Regulatory Compliance
Power Supply Requirements, Specifications, and Twist Lock Options
The requirements for Matrix X Router AC power supply modules are shown in 
The power specifications for Matrix X Router modules, shown in 
, and redundancy 
configuration tables, shown in 
 and 
, are useful guides for power budget 
planning. To estimate a power budget, simply total the wattage of each installed module, making 
sure the combined wattage consumed is no greater than 100% of the output of the power 
supply(ies).
For example, if you install one CM and FM, three fan trays, and six IOMs (X‐G32‐00) at 
1500 Watts/220 Vac, your total power required is 1735 watts. You would be required to install a 
minimum of two power supplies to support this configuration or three power supplies for N + 1 
redundancy. A second example including two CMs and FMs, six fan trays, and sixteen IOMs 
(X‐G32‐00s) at 1160 Watts/110 Vac would yield 3040 watts, requiring a minimum of three power 
supplies for this configuration or four power supplies for N + 1 redundancy.
Fan Tray
Dimensions
4.13 cm H x 12.7 cm W x 56.52 cm D
1.625 in. H x 5.0 in. W x 22.25 in. D
Weight
3.31 kg (7.3 lb)
MTBF (Predicted)
381,219 hours
Environmental
Operating Temperature
5°C to 40°C (41°F to 104 °F)
Storage Temperature
-30°C to 73°C (-22°F to 164°F)
Operating Relative Humidity
5% to 95% (non-condensing)
Table A-1 Matrix X-16C Specifications (continued)
Item
Specification
Table A-2 AC Power Supply Requirements
Item
Specification
Input Frequency
50 to 60 Hz
Input (Voltage/Current)
100 to 125 Vac: 16 A
200 to 240 Vac: 8 A
Output Power
1160/1500 Watts