Logging and Network Management Command Set
Configuring System Logging
11-16
11.2.1.12set logging application
Use this command to set the severity level of log messages for an application.
set logging application {mnemonic | all} level 
Table 11-2
show logging application Output Details
Output
What It Displays...
Application
Mnemonic values for applications being logged. For details 
on setting this value using the set logging application 
command, refer to 
For a list of valid values 
and their corresponding applications, refer to 
.
Current Severity 
Level
Severity level (from 1 to 8) at which the server is logging 
messages for the listed application. 
NOTE: Most system messages are logged at 
severity level of 6 (Notice). By default, the logging 
applications are set to 5 (Warning),
 
which will 
suppress level 6 (Notice) messages from the 
console session. To view most of the logging of 
configuration messages on the console session, 
ACL hits etc, the set logging application 
command should be used as described in 
 to set the logging level for 
applications to 6 or higher.