Справочник Пользователя для Fortinet Version 3.0

Скачать
Страница из 88
FortiBridge Version 3.0 Administration Guide
32
09-30000-0163-20061109
Installing FortiBridge unit firmware
Setting up FortiBridge units
Reverting to a previous firmware version
This procedure reverts the FortiBridge unit to a previous firmware version and 
rests the unit to its factory default configuration.
Before using this procedure you can backup the FortiBridge unit configuration 
using the command execute backup config.
To use the following procedure you must have a TFTP server that you can 
connect to from the FortiBridge unit.
To revert to a previous firmware version
1
Make sure that the TFTP server is running.
2
Copy the new firmware image file to the root directory of the TFTP server.
3
Log into the CLI as an administrator with sysshutdowngrp access.
Normally this would be the admin administrator. But you can use access profiles 
to control administrative access. See 
 for more 
information.
4
Make sure the FortiBridge unit can connect to the TFTP server.
You can use the following command to ping the computer running the TFTP 
server. For example, if the TFTP server's IP address is 192.168.1.168:
execute ping 192.168.1.168
5
Enter the following command to copy the firmware image from the TFTP server to 
the FortiBridge unit:
execute restore image <name_str> <tftp_ip>
Where <name_str> is the name of the firmware image file on the TFTP server 
and <tftp_ip> is the IP address of the TFTP server. For example, if the 
firmware image file name is FBG_1000-v10-build010-FORTINET.out and 
the IP address of the TFTP server is 192.168.1.23, enter:
execute restore image FBG_1000-v10-build010-FORTINET.out 
192.168.1.168 
The FortiBridge unit uploads the firmware image file. Once the file has been 
uploaded a message similar to the following is displayed:
Get image from tftp server OK.
This operation will downgrade the current firmware version!
Do you want to continue? (y/n)
6
Type Y.
The FortiBridge unit reverts to the old firmware version, resets the configuration to 
factory defaults, and restarts. This process takes a few minutes.
7
Reconnect to the CLI.
8
To confirm that the older version of the firmware image has been loaded, enter:
get system status