SAPTF33xx-1xx in the Network
Standard Configuration
One Unit A device (SAPTF33xx-100) and one Unit B device (SAPTF33xx-110)
are required for the standard configuration.  The Unit A device is connected to
the Central Office (CO) while the Unit B device is connected to a telephone
device.
Automatic Ring-Down Configuration
Automatic Ring Down (ARD) is a dedicated, point-to-point voice system.  When
one telephone is taken off-hook, the other telephone rings, without the need to
dial.  Two Unit B devices (SAPTF33xx-110), connected via the fiber ports, are
required for this mode of operation; with a telephone device at each end.  
SAPTF33xx-100
Unit A -- Emulates 
the telephone device
SAPTF33xx-110
Unit B -- Emulates the
Central Office (CO)
Central Office (CO)
SAPTF33xx-110
Unit B -- Emulates the 
Central Office (CO)
SAPTF33xx-110
Unit B -- Emulates the
Central Office (CO)
5
techsupport@transition.com
Click the “Transition Now” link for a live Web chat.
Installation 
CAUTION:  Wear a grounding device and observe electrostatic discharge
precautions when setting the jumpers.  Failure to observe this caution could
result in damage to, and subsequent failure of, the media converter.
Setting the Jumpers
1.
Using a small screwdriver, remove the screws that secure the cover to the
media converter and carefully remove the cover.
2.
Locate the jumpers on the circuit board.
3.
Using small needle-nosed pliers or similar device, move the jumper to the
desired position.  (Refer to the drawings below.)
4.
Carefully replace the cover on the media converter and replace the
screws to secure the cover.
Standard / Automatic Ring-Down
The jumper labeled “JP1” is used to switch between the Standard or Automatic
Ring-Down configuration and is located on the top  circuit board of Unit B
(SAPTF33xx-110)
.  
The drawing below illustrates the jumper settings.    
Set jumper JP1 on the Unit B device to the Standard setting when
using the Standard configuration (described on page 4).
Set jumper JP1 on both Unit B devices to the Automatic Ring-Down
setting when using the Automatic Ring-Down configuration
(described on page 4).
US / EU Telephone Regulation
The jumper labeled “US  EU” is used to switch between the US or EU
telephone configuration and is located on the top  circuit board of Unit A
(SAPTF33xx-100)
.  This feature is required to comply with the EU TBR21
telephone regulation.  The jumper has been set at the factory to the US setting
as the default.  
The drawing below illustrates the jumper settings.  
Set jumper “US  EU” on the Unit A device to the US setting if the
device is to be used with US-based telephone systems.
Set jumper “US  EU” on the Unit A device to the EU setting if the
device is to be used with European-based telephone systems.
Standard
1
3
Automatic
Ring-Down
1
3
JP1
JP1
US Setting
EU Setting
US
EU
US