14
4.5 Serial port configuration panel
The Serial Port Configuration panel configures the communication parameters for the RS-232 link on 
the FibreBridge. These settings must match settings selected on your host computer in order to establish 
a link. Some parameters will be “grayed out” if they do not apply to your model of the FibreBridge or 
if they have no effect based upon the selected value of a related parameter. 
The number of data bits is fixed at eight for the FibreBridge. 
Parity is always disabled.
Baud Rate (default = 9600)
Modifies the baud rate. The FibreBridge is capable of 2400, 
9600, 19200, 38400, 57600 or 115200 bits per second.
Flow Control (default = None)
Selects the method for data handshaking between the 
FibreBridge and the host computer. Serial port flow control 
can be managed using either hardware flow control, 
software flow control (Xon/Xoff) or no flow control.
Stop Bits (default = 1)
Configures the number of stop bits per character to either 
one or two.
Some options will be “grayed out” on the panel: they are not available because of the type of access mode or FibreBridge model or they have no effect based on other 
selections. The chart below shows options available based on model and access method.
Access method
Options
2200/3200 
in-band
2200/3200 
Ethernet
2200/3200 
serial port
4500 
in-band
4500 
Ethernet
4500 
serial port
Baud rate
Flow control
Stop bits