Справочник Пользователя для Avaya CMC1
Upgrading R9csi/R10csi/Communication Manager 1.x/2.x to Avaya Communication Manager 2.2 on an
224 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
To set daylight savings rules:
1. Type change daylight-savings-rules and press RETURN.
Note:
Note:
The default daylight savings rule is 0, meaning no daylight savings transition.
2. Type the appropriate Start and Stop information in the
Change Day
,
Month
,
Date
,
Time
,
and
Increment
fields for each rule. For example, 1:00 in the
Increment
field means to
move the clock forward or back by one hour at the transition point.
Note:
Note:
You can change any rule except rule 0 (zero). You cannot delete a daylight
savings rule if it is in use on either the Locations or Date and Time screens.
savings rule if it is in use on either the Locations or Date and Time screens.
3. Press ENTER.
Verify the upgrade
To verify the upgrade:
1. Type status system 1 and verify that the system is in a normal state.
Check these fields for the corresponding values:
●
In the
SPE ALARMS
section,
MAJOR
and
MINOR
alarms =
0
●
Service State
=
in service
2. Type display alarms and press RETURN.
If there are alarms, take the necessary corrective actions.
DAYLIGHT SAVINGS RULES
Rule
Change Day
Month
Date
Time
Increment
0: No Daylight Savings
1: Start: first Sunday___ on or after April
1
at _2:00
01:00
Stop: first Sunday___ on or after October
25 at _2:00
2: Start: first _________ on or after ________ __ at __:__
Stop: first _________ on or after ________ __ at __:__
3: Start: first _________ on or after ________ __ at __:__
Stop: first _________ on or after ________ __ at __:__
4: Start: first _________ on or after ________ __ at __:__
Stop: first _________ on or after ________ __ at __:__
5: Start: first _________ on or after ________ __ at __:__
Stop: first _________ on or after ________ __ at __:__