83
Corrective Actions:
Call the administrator of the remote module.
Wait for the signal to return.
Troubleshooting X330W-2USP
You can obtain statistical information regarding module performance, error rates, 
and DTE/DCE signal statuses using the 
show interfaces
 command. X330W-2USP 
does not indicate a failure via alarm LEDs.
X330W-2USP provides error messages in the following situations:
Cable connection fault
 - When there is a fault with the cable connections or 
when a DCE cable is connected. Check the cables and connections.
Host communication fault
 - When the X330WAN can not establish a 
connection with the host P330 switch. In this case, verify that the appropriate 
software versions are installed in the host P330 switch.
If X330WAN (or the connected DCE) reports data errors (CRC, etc.), there might 
exist a phase shift between the data and the accompanying clock. In this case use the 
invert txclock
 command to invert the transmit clock signal (TxC) from the DCE.
Using Loopbacks
The X330W-2DS1 module supports the following loopback types:
Diag Loopback (E1/T1)
 - The X330W-2DS1 CPU instructs the Line Framer to 
create a loop towards the CPU. A Blue Alarm (AIS) is sent on the line to the peer 
module. The Diag Loopback is illustrated in Figure 5.1.
Figure 5.1
Diag Loopback
Local Line Loopback (E1/T1)
 - The X330W-2DS1 Line Framer creates a loop on 
the line towards the peer module. The Local Line Loopback is illustrated in 
Figure 5.2.
X330WAN
CPU
Line
Framer
Tx
Rx
WAN
Blue Alarm
Blue Alarm