Hardware installation 
Inserting a FortiController-5103B board
FortiController-5103B Session-Aware Load Balancer Guide
10-500-161552-20140822
17
The FortiController-5103B handles align the board in the chassis slot and are used to 
insert and eject the board from the slot. The right (bottom) handle activates a microswitch 
that turns on or turns off power to the board. When the right (bottom) handle is open the 
microswitch is off and the board cannot receive power. When the right (bottom) handle is 
fully closed the microswitch is on and if the board is fully inserted into a chassis slot the 
board can receive power. 
Inserting a FortiController-5103B board
The FortiController-5103B board must be fully installed in a chassis hub/switch slot 
(usually slot 1 or 2), with the handles closed and locked and retention screws fully 
tightened for the FortiController-5103B board to receive power and operate normally. If 
the FortiController-5103B board is not receiving power, the HS LED glows solid blue and 
all other LEDs remain off. See 
.
It is important to carefully seat the FortiController-5103B board all the way into the 
chassis, to not use too much force on the handles, and to make sure that the handles are 
properly locked. Only then will the FortiController-5103B board power-on and start up 
correctly.
FortiController-5103B boards are hot swappable. The procedure for inserting 
a FortiController-5103B board into a chassis slot is the same whether or not the chassis 
is powered on.
To insert a FortiController-5103B board into a chassis slot
To complete this procedure, you need:
A FortiController-5103B board
An ATCA chassis with an empty hub/switch slot
An electrostatic discharge (ESD) preventive wrist strap with connection cord
Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal 
surface on the chassis or frame.
If required, remove the protective metal frame that the FortiController-5103B board 
has been shipped in.
Insert the FortiController-5103B board into the empty hub/switch slot in the chassis.
You can reset the board without removing it from the chassis. See 
Do not carry the FortiController-5103B board by holding the handles or retention 
screws. When inserting or removing the FortiController-5103B board from a chassis slot, 
handle the board by the front panel. The handles are not designed for carrying the 
board. If the handles become bent or damaged the FortiController-5103B board may not 
align correctly in the chassis slot.
FortiController-5103B boards must be protected from static discharge and physical 
shock. Only handle or work with FortiController-5103B boards at a static-free 
workstation. Always wear a grounded electrostatic discharge (ESD) preventive wrist 
strap when handling FortiController-5103B boards.