Hardware installation 
Shutting down and Removing a FortiController-5103B board
FortiController-5103B Session-Aware Load Balancer Guide
10-500-161552-20140822
19
If the board has not been inserted properly the HS LED changes to solid blue and all 
other LEDS turn off. If this occurs, open the handles, slide the board part way out, and 
repeat the insertion process.
Once the board is inserted correctly, fully tighten the retention screws to lock the 
FortiController-5103B board into position in the chassis slot.
Shutting down and Removing a FortiController-5103B board
To avoid potential hardware problems, always shut down the FortiController-5103B 
operating system properly before removing the FortiController-5103B board from a 
chassis slot or before powering down the chassis.
The following procedure describes how to correctly use the FortiController-5103B 
mounting components described in 
 to remove a FortiController-5103B board from an ATCA chassis slot.
FortiController-5103B boards are hot swappable. The procedure for removing 
a FortiController-5103B board from a chassis slot is the same whether or not the chassis 
is powered on.
To remove a FortiController-5103B board from a chassis slot
To complete this procedure, you need:
An ATCA chassis with a FortiController-5103B board installed
Table 4:   FortiController-5103B normal operating LEDs
LED
State
OOS
Off
Power
Green
Status
Off
ACC
Off (Or flashing green when the system accesses the 
FortiController-5103B flash disk.)
IPM
Off
Tighten
Retention
Screw
Do not carry the FortiController-5103B board by holding the handles or retention 
screws. When inserting or removing the FortiController-5103B board from a chassis slot, 
handle the board by the front panel. The handles are not designed for carrying the 
board. If the handles become bent or damaged the FortiController-5103B board may not 
align correctly in the chassis slot.