Справочник Пользователя для Toshiba 3511
e-STUDIO3511/4511 ADJUSTMENT
3 - 2
November 2003 © TOSHIBA TEC
3.2 Adjustment of the Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
(1)
Install the cleaner and developer unit.
Note:
Do not install the toner cartridge.
(2)
While pressing [0] and [5] simultaneously, turn the power ON. The following message will be
displayed.
100%
A
A3
TEST MODE
[0] [5]
[POWER]
→
(3)
Key in a code and press the [START] button.
Code 200: All developer materials 201: Developer material Y
202: Developer material M
203: Developer material C
204: Developer material K
206: Developer material Y, M, C
(4)
Adjustment for “K” (Magnetometric sensor control)
• The following message will be displayed approx. 2 minutes later.
100%
200
A3
TEST MODE
(Code)
→ [START]
→
K: xxxV
K: zzzV
(B)
→
(C)
→
(A)
→
(B): Current sensor voltage (V)
(C): No display
(A): Target values (V) for adjustment reference
voltage
Note:
The current sensor voltage (V) shown in (B) automatically changes, gradually approaching the
target value for adjustment reference voltage shown in (A).