Справочник Пользователя для Citizen Systems CT-S300

Скачать
Страница из 32
— 26 —
5.2  Manual Setting of Memory Switch
Memory switches can be set manually or by a command.
For manual setting, refer to the next page.
The function of each memory switch is shown in the following table.  (The
white-on-black characters 
are factory setting.)
Switch No.
Setting
0 (OFF)
1 (ON)
Memory SW1-1
Power ON Info
Send
Not send
Memory SW1-2
Buffer Size
4k bytes
45 bytes
Memory SW1-3
Busy Condition
Full/Err
Full
Memory SW1-4
Receive Error
Print “?”
No Print
Memory SW1-5
CR mode
Ignored
LF
Memory SW1-6
Reserved
Fixed
Memory SW1-7
DSR Signal
Invalid
Valid
Memory SW1-8
Init Signal
Invalid
Valid
Memory SW2-1
Reserved
Fixed
Memory SW2-2
Auto Cutter
Invalid
Valid
Memory SW2-3
Spool Print
Invalid
Valid
Memory SW2-4
Full Col Print
CBM1000
EPSON
Memory SW2-5
Resume aft PE
Next
Top
Memory SW2-6
Paper width
80 mm
58 mm
Memory SW2-7
Reserved
Fixed
Memory SW2-8
NPE Sensor
Valid
Invalid
Memory SW3-1
Resum Cttr Err
Feed S/W
Command
Memory SW3-2
Resum Open Err
Close
Command
Memory SW3-3
Parallel 31 Pin
Valid
Invalid
Memory SW3-4
Paper Select
Thermal
Black MK
Memory SW3-5
Column Number
48/32 col
42/30 col
Memory SW3-6
No use
Fixed
Memory SW3-7
CBM1000 Mode
Invalid
Valid
Memory SW3-8
Open w/Printing
Auto
Manual
Memory SW4-1
Auto Length
Invalid
Valid
Memory SW4-2
BM Sensor
Surface
Back
Memory SW4-3
No use
OFF
Fixed
Memory SW4-4
No use
OFF
Fixed
Memory SW4-5
No use
OFF
Fixed
Memory SW4-6
No use
OFF
Fixed
Memory SW4-7
No use
OFF
Fixed
Memory SW4-8
Full Cut Cmd
Full Cut
Partial