Справочник Пользователя для Samsung SRP-500

Скачать
Страница из 41
 
 
17 
 
2-5. You want to check a software program. 
•  Hexadecimal Dump 
This feature allows experienced users to see exactly what data is coming 
to the printer. This can be useful in finding software problems. When you 
turn on the hexadecimal dump function, the printer prints all commands 
and other data in hexadecimal format along with a guide section to help 
you find specific commands. 
 
To use the hexadecimal dump feature, follow these steps: 
 
1)  After you make sure that the printer is off, open the front cover of the 
printer. 
2)  Hold down the Feed button while you turn on the printer. 
3)  Close the front cover. 
4)  Run any software program that sends data to the printer. The printer 
prints “Hexadecimal Dump” and then all the codes it receives in a two – 
column format. The first column contains the hexadecimal codes and 
the second column gives the ASCII characters that correspond to the 
codes. 
 
 
•  A period(.) is printed for each code that has no ASCII equivalent. 
 
5)  When the printing finishes, turn off the printer. 
 
 
 
 18 
 
Chapter 3
 
 
 
DIP switch settings 
 
 
Although the factory settings are best for almost all users, if you have special 
requirements, you can change the DIP switch. 
3-1. Setting the DIP switches 
•  DIP switch functions 
Your printer has two sets of DIP switches. 
The functions of the switches are shown in the following table. 
DIP - SW1 
Switch 
Function 
ON 
OFF 
Default 
1-1 
OFF 
1-2 
Emulation Selection 
Refer to the following table 
OFF 
1-3 Auto 
cutter  Enable Disable 
OFF 
1-4 
Cartridge 
one cartridge 
two cartridges 
OFF 
1-5 Density
*1)
 Bold 
Normal 
OFF 
1-6 Special 
Function 
*2)
 Enable  Disable  OFF 
1-7 
Near end sensor 
Enable 
Disable 
OFF 
1-8 Low 
ink 
check  Disable  Enable  OFF 
 
 
1-1 
1-2 
EPSON OFF
OFF
STAR OFF
ON 
CITIZEN ON 
OFF
EPSON-KP 
*3)
ON ON 
 
DIP - SW2 (RS232C Serial interface model)
 
Switch 
Function 
ON 
OFF 
Default 
2-1 
Data receive error 
Print “?” 
Ignore 
OFF 
2-2 Reserved  OFF 
2-3  Hand 
Shaking 
DTR/DSR XON/XOFF OFF 
2-4 Word 
length 
7bit 
8bit  OFF 
2-5 Parity 
check  Enable  Disable OFF 
2-6 Parity 
selection 
EVEN 
ODD  OFF 
2-7 
OFF 
2-8 
Baud rate selection 
Refer to the following table 
OFF 
 
DIP - SW2 (Parallel interface model)
 
Switch 
Function 
ON 
OFF 
Default 
2-1 
Auto Line Feed 
Enable 
Disable 
OFF 
2-2 
OFF 
2-3 
OFF 
2-4 
OFF 
2-5 
OFF 
2-6 
OFF 
2-7 
OFF 
2-8 
Undefined 