Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
4 - 17 
MELSEC-Q
4   INSTALLATION, WIRING AND MAINTENANCE OF THE PRODUCT 
 
4.4 Confirming the installation and wiring 
4.4.1 Items to confirm when installation and wiring are completed 
Check the following points when completed with the QD75MH installation and wiring. 
 
 Is the module correctly wired? ... "Connection confirmation" 
With "connection confirmation", the following three points are confirmed using GX 
Configurator-QP's connection confirmation function. (GX Configurator-QP is 
required for this "connection confirmation".) 
 
  
  Are the QD75MH and servo amplifier correctly connected? 
  
  Are the servo amplifier and servomotor correctly connected? 
  
  Are the QD75MH and external device (input/output signal) correctly 
connected? 
 
With this "connection confirmation", "whether the direction that the QD75MH 
recognizes as forward run matches the address increment direction in the actual 
positioning work", and "whether the QD75MH recognizes the external 
input/output signals such as the near-point dog signal and stop signal" can be 
checked. 
 
Refer to GX Configurator-QP Operating Manual for details on "Connection 
confirmation". 
 
Note that the monitor data of the " 
Md.30
 External input signal" in the GX 
Developer may also be used to "confirm the connection between the QD75MH 
and external device (input signals)". 
 
 
Important 
 
If the QD75MH is faulty, or when the required signals such as the near-point dog signal and stop signal 
are not recognized, unexpected accidents such as "not decelerating at the near-point dog during 
machine OPR and colliding with the stopper", or "not being able to stop with the stop signal" may occur. 
The "connection confirmation" must be carried out not only when structuring the positioning system, but 
also when the system has been changed with module replacement or rewiring, etc.