Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
5 - 84 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
 
 
 
 
Item  2 Setting 
details 
Setting value 
 
C: Feedback position 
(   10V/1 x 10
8
[PLS]) 
(Note-1), 
(Note-3)
 
 
Pr.173  
(PC10) 
Analog monitor output 2 
Used to set the output signal from analog monitor 
output 2 of the servo amplifier. 
(Note-1): Encoder pulse unit. 
(Note-2): 8V is outputted at the maximum torque. 
(Note-3): It can be used by absolute position 
detection system. 
D: Bus voltage 
(   8V/400V) 
 
Pr.174  
(PC11) 
Analog monitor 1 offset 
Used to set the offset voltage of the analog monitor 1 
(MO1) output. 
-999 to 999[mV] 
 
Pr.175  
(PC12) 
Analog monitor 2 offset 
Used to set the offset voltage of the analog monitor 2 
(MO2) output. 
-999 to 999[mV] 
 
E
xpans
ion s
et
ting 
Pr.180  
(PC17) 
Function selection C-4 
• Home position setting condition in the absolute 
position detection system can be selected.  
• Used to set this parameter for the absolute position 
encoder. 
0: Need to pass motor Z phase 
after the power supply is 
switched on. 
1: Not need to pass motor Z 
phase after the power supply 
is switched on.