5   DATA USED FOR POSITIONING CONTROL 
 
Storage item 
Storage details 
 
 
 
 
 
Md.108
 Servo status 
This area stores the servo status. 
 Zero point pass 
Turns ON if the zero point of the encoder has been passed even once. 
 Zero speed 
Turns ON when the motor speed is lower than the servo parameter “zero speed.” 
 READY ON 
Indicates the ready ON/OFF. 
 Servo ON 
Indicates the servo ON/OFF. 
 Servo alarm 
Turn ON during the servo alarm. 
 In-position 
The dwell pulse turns ON within the servo parameter “in-position.” 
 Torque limit 
Turns ON when the servo amplifier is having the torque restricted. 
 Absolute position lost 
Turns ON when the servo amplifier is lost the absolute position. 
 Servo warning 
Turn ON during the servo warning. 
 Update timing : 1.7ms 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Md.109
 Regenerative load ratio 
 The rate of regenerative power to the allowable regenerative power is indicated 
as a percentage. 
 When the regenerative option is used, the rate to the allowable regenerative 
power of the option is indicated. 
(Buffer memory) % 
 Update timing: 1.7 ms 
 
 
 
 
 
 
 
Md.110
Effective load torque 
 The continuous effective load torque is indicated. 
 The average value of the load rates for the past 15 seconds to the rated torque is 
stored as a percentage, rated torque being 100%. 
(Buffer memory) % 
 Update timing: 1.7 ms 
 
 
 
 
 
 
 
Md.111
Peak torque ratio 
 The maximum torque is indicated. (Holding value) 
 The peak values for the past 15 seconds are indicated, rated torque being 100%. 
(Buffer memory) % 
 Update timing: 1.7 ms