5   DATA USED FOR POSITIONING CONTROL 
 
5.7 List of control data 
5.7.1 System control data 
Setting item 
Setting details 
 
 
 
 
 
Cd.1
Flash ROM write request 
 Requests writing of data (parameters, positioning data, and block start data) from 
the buffer memory to the flash ROM. 
POINT  
(1) Do not turn the power OFF or reset the PLC CPU while writing to the flash ROM. 
If the power is turned OFF or the PLC CPU is reset to forcibly end the process, 
the data backed up in the flash ROM will be lost. 
(2) Do not write the data to the buffer memory before writing to the flash ROM is 
completed.  
(3) The number of writes to the flash ROM with the PLC program is 25 max. while 
the power is turned ON. 
Writing to the flash ROM beyond 25 times will cause an error (error code: 805). 
Refer to Section 15.2 "List of errors" for details.  
(4) Monitoring is the number of writes to the flash ROM by the "
Md.19
No. of write 
accesses to flash ROM". 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Requests initialization of setting data. 
Initialization: Resetting of setting data to default values 
Note: After completing the initialization of setting data, reset the PLC CPU or reboot 
the PLC power. 
 
  Initialized setting data 
 
  Parameters (
Pr.1
to
Pr.57
,  Pr.80   to  Pr.84 , Pr.100 to Pr.204)   
Positioning data (No. 1 to 600) 
 
Block start data (No. 7000 to 7004) 
 
 
Cd.2
Parameter initialization request 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Cd.41 
Deceleration start flag valid
 
 Set whether "
 Md.48 
Deceleration start flag" is made valid or invalid. 
POINT  
The "
 Cd.41 
Deceleration start flag valid" become valid when the PLC READY 
signal [Y0] turns from OFF to ON. 
 
 
 
 
 
 
 
 
 
 Cd.42 
Stop command processing 
for deceleration stop 
selection
 
 Set the stop command processing for deceleration stop function (deceleration 