6   PLC PROGRAM USED FOR POSITIONING CONTROL 
 
[2]   Starting by inputting external command signal 
When starting positioning control by inputting the external command signal, the 
start command can be directly input into the QD75MH. This allows the variation 
time equivalent to one scan time of the PLC CPU to be eliminated. This is an 
effective procedure when operation is to be started as quickly as possible with 
the start command or when the starting variation time is to be suppressed. To 
start positioning control by inputting the external command signal, set the "data 
required to be set" and then turn ON the external command signal. 
 
 Restrictions 
 
When starting by inputting the external command signal, the start complete signal 
[X10, X11, X12, X13] will not turn ON. 
 
 Data required to be set 
 
To execute positioning start with the external command signal, set parameter 
(
Pr.42
) beforehand, and validate the "external command signal" with the 
"external command signal validity setting program (program No. 5). 
 
Buffer memory address 
Setting item 
Setting 
value 
Setting details 
Axis 1  Axis 2  Axis 3  Axis 4 
Pr.42
 
External command 
function selection 
Set to "0: External positioning start". 
62 
212 
362 
512 
Cd.8
 
External command valid 
Set to "1: Validate external command". 
1505  1605  1705  1805 
 
 Refer to Chapter 5 "Data Used for Positioning Control" for details on the setting details. 
 
 Starting time chart 
 
0
V
t
1(00)
External command signal
1
0
1
Cd.  8  External command valid
Dwell time
Operation pattern
Positioning start signal
PLC READY signal
QD75 READY signal
Positioning start complete  signal
BUSY signal
Error detection signal
Positioning complete signal
Positioning data No.
Pr. 42  External command function selection
Cd.  3  Positioning start No.
[Y10]
[Y0]
[X0]
[X10]
[XC]
[X14]
[X8]
All axis servo ON
[Y1]
 
 
Fig. 6.11 Time chart for starting with external start signal