Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
1 - 26 
MELSEC-Q
 
1   PRODUCT OUTLINE 
 
1.2.3 Outline of stopping 
Each control is stopped in the following cases. 
 
(1)  When each control is completed normally. 
(2)  When the Servo READY signal is turned OFF. 
(3)  When a PLC CPU error occurs. 
(4)  When the PLC READY signal is turned OFF. 
(5)  When an error occurs in the QD75MH. 
(6)  When control is intentionally stopped (Stop signal from PLC CPU turned ON, stop 
signal from an external device, etc.). 
 
The outline for the stopping process in these cases is shown below. (Excluding (1) for 
normal stopping.) 
 
Stop process 
OPR control 
Manual control 
Stop cause 
Stop 
axis 
M code 
ON signal 
after stop 
Axis 
operation 
status 
after 
stopping 
(
Md.26
Machine 
OPR 
control 
Fast 
OPR 
control 
Major 
positioning 
control 
High-level 
positioning 
control 
JOG/ 
Inching 
operation 
Manual 
pulse 
generator 
operation 
"Forced stop 
input signal 
from external 
device" OFF 
All 
axes 
No 
change 
Servo 
OFF 
Servo 
READY OFF 
 • Servo amplifier 
power supply 
OFF
 
Servo 
amplifier 
disconnected 
 • Servo alarm
 
During 
error 
Forced stop 
 • Forced stop 
input to servo 
amplifier 
Each 
axis 
No 
change 
Servo 
OFF 
Servo OFF or free run 
(The operation stops with dynamic brake or 
electromagnetic brake.) 
 
Fatal stop 
(Stop group 1) 
Hardware 
stroke limit 
upper/lower 
limit error 
occurrence 
Each 
axis 
No 
change 
During 
error 
Deceleration stop/sudden stop 
(Select with "
Pr.37
Sudden stop group1 
sudden stop selection" ) 
Deceleration 
stop 
Error occurs 
in PLC CPU 
No 
change 
PLC READY 
signal OFF 
Turns 
OFF 
Emergency 
stop  
(Stop group 2) 
Error in test 
mode 
All 
axes 
No 
change 
During 
error 
Deceleration stop/sudden stop  
(Select with "
Pr.38
Sudden stop group2 
sudden stop selection" ) 
Deceleration 
stop 
Axis error 
detection 
(Error other 
than stop 
group 1 or 2) 
Relatively safe 
stop  
(Stop group 3)  "Stop signal" 
from 
peripheral 
device 
Each 
axis 
No 
change 
During 
error 
Deceleration stop/sudden stop  
(Select with " 
Pr.39
 Sudden stop group3 
sudden stop selection" ) 
Deceleration 
stop