12   CONTROL SUB FUNCTIONS 
 
12.2 Sub functions specifically for machine OPR 
The sub functions specifically for machine OPR include the "OPR retry function" and 
"OP shift function". Each function is executed by parameter setting.  
 
12.2.1 OPR retry function 
When the workpiece goes past the OP without stopping during positioning control, it 
may not move back in the direction of the OP although a machine OPR is commanded, 
depending on the workpiece position. This normally means the workpiece has to be 
moved to a position before the near-point dog by a JOG operation, etc., to start the 
machine OPR again. However, by using the OPR retry function, a machine OPR can 
be carried out regardless of the workpiece position.  
 
The details shown below explain about the "OPR retry function".  
  [1] Control details 
  [2] Precautions during control 
  [3] Setting the OPR retry function 
 
[1]  Control details 
The following drawing shows the operation of the OPR retry function. 
(1)   OPR retry point return retry operation when the workpiece is within the range 
between the upper and lower limits.  
 
1)  The movement starts in the "
Pr.44
 OPR direction" by a machine OPR start.  
2)  The operation decelerates when the limit signal OFF is detected. 
3)  After stopping due to the limit signal OFF detection, the operation moves at the "
Pr.46
 OPR speed" in 
the opposite direction of the "
Pr.44
 OPR direction".  
4)  The operation decelerates when the near-point dog turns OFF. 
5)  After stopping due to the near-point dog OFF, a machine OPR is carried out in the "
Pr.44
 OPR 
direction".  
6)  Machine OPR completion
 
5)
1)
Near-point dog
Limit signal OFF
ON
2)
3)
6)
4)
Zero signal
Hardware limit switch
 
Fig. 12.1 OPR retry operation by limit signal detection