12 - 7 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
[2]   Precaution during control 
(1)  The following table shows whether the OPR retry function may be executed 
by the "
Pr.43
 OPR method".  
 
Pr.43
OPR method 
Execution status of OPR retry function 
Near-point dog method 
  :  Execution possible 
Count method 1) 
  :  Execution possible 
Count method 2) 
  :  Execution possible 
Data set method 
  : 
 
(2)  Always establish upper/lower limit switches at the upper/lower limit positions 
of the machine, and connect an QD75MH module. If the OPR retry function 
is used without hardware stroke limit switches, the motor will continue 
rotation until a hardware stroke limit signal is detected. 
 
(3)  Always wire QD75MH upper/lower limit switches even when the OPR 
function is invalidated. Control cannot be carried out with the QD75MH 
unless the wiring is carried out. 
 
(4)  Do not carry out settings so that the servo amplifier power turns OFF by the 
upper/lower limit switches connected to the QD75MH. If the servo amplifier 
power is turned OFF, the OPR retry cannot be carried out. 
 
(5)  The operation decelerates upon detection of the hardware limit signal, and 
the movement starts in the opposite direction. In this case, however, an 
error (104, 105) is not produced. 
 
[3]   Setting the OPR retry function 
To use the "OPR retry function", set the required details in the parameters shown 
in the following table, and write them to the QD75MH. 
When the parameters are set, the OPR retry function will be added to the 
machine OPR control. The set details are validated at the rising edge (OFF   
ON) of the PLC READY signal (Y0). Set "
Pr.57
 Dwell time during OPR retry" 
according to the user's requirements. 
 
Setting item 
Setting 
value 
Setting details 
Factory-set 
initial value 
 Pr.48    OPR retry 
Set "1: Carry out OPR retry by limit switch". 
 Pr.57   
Dwell time during 
OPR retry 
 
Set the deceleration stop time during OPR retry. 
(Random value between 0 and 65535 (ms)) 
 
                   Refer to Section 5.2 "List of parameters" for setting details. 
 
REMARK 
 Parameters are set for each axis.  
 It is recommended that the parameters be set whenever possible with GX 
Configurator-QP. Execution by PLC program uses many PLC programs and 
devices. The execution becomes complicated, and the scan times will increase.