Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
12 - 22 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
(3)  When continuous path control of a circular interpolation is being carried out in 
the near pass, an address in which the extra movement amount is subtracted 
from the positioning address of the positioning data currently being executed is 
replaced by the starting point address of the next positioning data No.  
Because the starting point address will be replaced, a large arc error deviation 
(error code: 506) may occur.  
In this case, adjust the "
Pr.41
 Allowable circular interpolation error width".  
Address designated by positioning data No.1
Path of positioning
address pass
Positioning data No.2
Positioning data No.1
Positioning data No.2
starting point address
during the near pass
Path of near pass
 
Fig. 12.11 Arc error during the near pass 
 
(4)  When a circle center is designated to continuously designate the circular 
interpolation control by a continuous path designation in the near pass, and 
the positioning address and starting point address of that arc are the same 
address, the path will make one circle using the two data items. This is 
because the 2nd data starting point address is shifted by the extra amount of 
the movement amount occurring from the 1st data.  
Path of positioning data No.1
Starting point address of positioning data No.1
Starting point address of 
positioning data No.2
Path of positioning data No.2
[Near pass]
Example