Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
12 - 20 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
12.3.3 Near pass function 
When continuous pass control is carried out using interpolation control, the near pass 
function is carried out. 
 
The "near pass function" is a function to suppress the mechanical vibration occurring at 
the time of switching the positioning data when continuous pass control is carried out 
using interpolation control. 
 
[Near pass function] 
The extra movement amount occurring at the end of each positioning data unit being 
continuously executed is carried over to the next positioning data unit.  Alignment is not 
carried out, and thus the output speed drops are eliminated, and the mechanical 
vibration occurring during speed changes can be suppressed.  Because alignment is 
not carried out, the operation is controlled on a path that passes near the position set 
in "
Da.6
Positioning address/movement amount". 
 
The details shown below explain about the "near pass function".  
  [1] Control details 
  [2] Precautions during control 
 
[1]   Control details 
The following drawing shows the path of the continuous path control. 
 
[The path of the near pass] 
Da. 6 Positioning address 
Path of positioning data No. 4
V
t
Positioning data No. 3
Speed dropping does not occur.
Path of positioning data No.3
Positioning data No. 4
 
Fig. 12.9 The path of the continuous path control