12   CONTROL SUB FUNCTIONS 
 
12.4.4 Hardware stroke limit function 
 
!
 DANGER 
When the hardware stroke limit is required to be wired, ensure to wire it in the negative logic using b-contact.  
If it is set in positive logic using a-contact, a serious accident may occur.  
 
In the "hardware stroke limit function", limit switches are set at the upper/lower limit of 
the physical moveable range, and the control is stopped (by deceleration stop) by the 
input of a signal from the limit switch. Damage to the machine can be prevented by 
stopping the control before the upper/lower limit of the physical moveable range is 
reached. 
The hardware stroke limit is able to use "external input connector" of the QD75MH or 
servo amplifier. (Refer to the "
 Pr.80 
 External signal selection".) 
 
The details shown below explain about the "hardware stroke limit function".  
  [1] Control details 
  [2] Wiring the hardware stroke limit  
  [3] Precautions during control 
  [4] When the hardware stroke limit is not used 
 
[1]   Control details 
The following drawing shows the operation of the hardware stroke limit function.