Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
12 - 36 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
(2)  For an external input signal of the servo amplifier
Mechanical stopper
Mechanical stopper
QD75MH
Movement 
direction
Deceleration stop at 
lower limit switch detection
QD75MH control moveable range
Lower limit
Upper limit
Start
Lower limit switch
Servo amplifier
SSCNET 
Start
Movement 
direction
Deceleration stop at 
upper limit switch detection
Upper limit switch
Deceleration stop at 
lower limit switch detection
Lower limit switch
Deceleration stop at 
upper limit switch detection
Upper limit switch
Servo amplifier
QD75MH
(1)  For an external input signal of QD75MH
Mechanical stopper
Mechanical stopper
Movement 
direction
Movement 
direction
Start
Start
QD75MH control moveable range
Lower limit
Upper limit
 
Fig. 12.18 Hardware stroke limit function operation