12   CONTROL SUB FUNCTIONS 
 
(2) When OPR request flag (
Md.31
 Status: b3) is ON, starting Fast OPR will 
result in an "Home positioning return (OPR) request flag ON" error (error 
code: 207) despite the setting value of "
 Pr.55
Operation setting for 
incompletion of OPR", and Fast OPR will not be performed. 
 
[3]   Setting method of "Operation setting for incompletion of OPR" 
 
The use the "Operation setting for incompletion of OPR", set the following 
parameters using a PLC program. 
 
Buffer memory address 
Setting item 
Setting 
value 
Setting details 
Axis 
Axis 
Axis 
Axis 
 Pr.55  
Operation setting 
for incompletion of 
OPR 
 
Set the operation setting for incompletion of 
OPR. 
   0: Positioning control is not executed. 
   1: Positioning control is executed. 
87  237 387 537 
 