12 - 106 
MELSEC-Q
 
12   CONTROL SUB FUNCTIONS 
 
12.8.2 Follow up function 
(1)   Follow up function 
The follow up function monitors the number of motor rotations (actual present 
value) with the servo OFF and reflects the value in the present feed value. 
Therefore, even if the servomotor rotates while the servo OFF, the servomotor 
will not just rotate for the quantify of droop pulses the next time the servo turns 
ON but positioning can be performed from the stop position. 
 
(2)   Execution follow up 
Follow up function is executed continually during the servo OFF status. 
 
OFF
Follow up function executed
ON
0
All axis servo ON (Y1)
Each axis servo OFF
command
Servo ON or OFF status
OFF
ON
Servo error detected
 
Fig. 12.56 Operation timings of follow up function 
 
 
POINT 
 
 The follow-up function performs the process if the "QD75MH and the servo 
amplifier is turned ON" and "servo OFF" regardless of the presence of the 
absolute position system.