14   DEDICATED INSTRUCTIONS 
 
[Functions] 
 (1) The PFWRT instruction completion can be confirmed using the complete devices 
((D)+0) and ((D)+1). 
 
(a)  Complete device ((D)+0) 
This device is turned ON by the END processing of the scan for which PFWRT 
instruction is completed, and turned OFF by the next END processing. 
 
(b)  Complete state display device ((D)+1) 
This device is turned ON and OFF according to the state in which PFWRT 
instruction is completed. 
  • When completed normally 
: Kept unchanged at OFF. 
  • When completed abnormally : This device is turned ON by the END 
processing of the scan for which PFWRT 
instruction is completed, and turned OFF by 
the next END processing. (same ON/OFF 
operation as complete device). 
 
END 
processing
END 
processing
END 
processing
END 
processing
OFF
OFF
OFF
ON
ON
ON
When 
completed 
abnormally
When 
completed normally
1 scan
PFWRT instruction
execution completion
PLC program
PFWRT instruction
Complete device
Complete state display 
device
[Instruction symbol]
[Execution condition]
PFWRT
ZP.PFWRT
"Un"
(S)
(D)
 
 
[Errors] 
(1)  When a dedicated instruction is completed abnormally, the error complete signal 
((D)+1) is turned ON, and the error code is stored in the complete status ((S)+1). 
Check and take measures against the error referring to Section 15.2 List of error 
codes.