Справочник Пользователя для Mitsubishi Electronics QD75MH2

Скачать
Страница из 838
 
 
 
15 - 4 
MELSEC-Q
 
15   TROUBLESHOOTING 
 
(3)  Servo amplifier detection warnings 
These are warning that occur at the hardware error such as servo amplifier 
and servomotor or the inapplicable servo parameters. 
Error or normality operation can't be executed by waning when warning is left 
as it is though servo off isn't executed. 
If you remove a warning factor, reset the servo amplifier. 
 
(4)  Types of warning codes  
 
Warning code 
Classification of warnings 
001 to 199 
Common warnings 
300 to 399 
JOG operation warnings 
400 to 499 
Manual pulse generator operation warnings 
500 to 599 
Positioning operation warnings 
900 to 999 
System control data setting range check warnings 
2090 to 2999 
Servo amplifier warnings 
(The contents of a vary in the model of servo amplifier.) 
 
 Warning storage 
 
(1)  When an axis warning occurs, the warning code corresponding to the warning 
details is stored in the following buffer memory (
Md.24
Axis warning No.) for 
axis warning No. storage. 
 
Axis No. 
Buffer memory address 
1 807 
2 907 
3 1007 
4 1107 
 
(2)  When an axis warning occurs in a positioning operation, etc., "1" is set in bit 9 
(b9) of the following buffer memory (
Md.31
Status) for axis status storage.  
 
Axis No. 
Buffer memory address 
1 817 
2 917 
3 1017 
4 1117 
 
[3]   Resetting errors and warnings 
An error or warning state is canceled after the following processing has been 
carried out by setting a "1" in the address [1502 (for axis 1)], [1602 (for axis 2)], 
[1702 (for axis 3)], and [1802 (for axis 4)] of the buffer memory for axis error 
resetting (
Cd.5
Axis error reset). 
 
 Axis error detection signal turned OFF 
 "
Md.23
 Axis error No." cleared 
 "
Md.24
 Axis warning No." cleared 
 Changing of "
Md.26
 operation status" from "Error" to "Standby". 
 "
Md.31
 Axis warning detection (b9)" turned OFF