Справочник Пользователя для IBM Type 7977

Скачать
Страница из 124
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
on
 
the
 
IBM
 
System
 
x
 
Documentation
 
CD
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Lit
 
light
 
path
 
diagnostics
 
LED
 
with
 
the
 
system-error
 
or
 
information
 
LED
 
also
 
lit
 
Description
 
Action
 
TEMP
 
A
 
system
 
temperature
 
or
 
component
 
has
 
exceeded
 
specifications.
 
Note:
 
A
 
fan
 
LED
 
might
 
also
 
be
 
lit.
 
1.
   
See
 
the
 
BMC
 
log
 
or
 
the
 
system-error
 
log
 
(see
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
on
 
the
 
IBM
 
System
 
x
 
Documentation
 
CD)
 
for
 
the
 
source
 
of
 
the
 
fault.
 
2.
   
Make
 
sure
 
that
 
the
 
airflow
 
in
 
the
 
server
 
is
 
not
 
blocked.
 
3.
   
If
 
a
 
fan
 
LED
 
is
 
lit,
 
reseat
 
the
 
fan.
 
4.
   
Replace
 
the
 
fan
 
for
 
which
 
the
 
LED
 
is
 
lit.
 
5.
   
Make
 
sure
 
that
 
the
 
room
 
is
 
neither
 
too
 
hot
 
nor
 
too
 
cold
 
(see
 
“Environment”
 
in
 
 
CPU
 
A
 
microprocessor
 
has
 
failed,
 
is
 
missing,
 
or
 
has
 
been
 
incorrectly
 
installed.
 
Note:
 
(Trained
 
service
 
technician
 
only)
 
Make
 
sure
 
that
 
the
 
microprocessors
 
are
 
installed
 
in
 
the
 
correct
 
sequence.
 
1.
   
Check
 
the
 
BMC
 
log
 
or
 
the
 
system-error
 
log
 
to
 
determine
 
the
 
reason
 
for
 
the
 
lit
 
LED.
 
2.
   
Find
 
the
 
failing,
 
missing,
 
or
 
mismatched
 
microprocessor
 
by
 
checking
 
the
 
LEDs
 
on
 
the
 
system
 
board.
 
3.
   
(Trained
 
service
 
technician)
 
Reseat
 
the
 
failing
 
microprocessor.
 
4.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
(Trained
 
service
 
technician
 
only)
 
Failing
 
microprocessor
 
b.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
S_ERR
 
Reserved
 
VRM
 
A
 
dc-dc
 
regulator
 
has
 
failed
 
or
 
is
 
missing.
 
Note:
 
This
 
error
 
is
 
for
 
either
 
the
 
VRM
 
or
 
integrated
 
VRD.
 
If
 
the
 
VRD
 
has
 
failed,
 
the
 
system
 
board
 
must
 
be
 
replaced
 
by
 
an
 
trained
 
service
 
technician.
 
1.
   
Check
 
the
 
BMC
 
log
 
or
 
the
 
system-error
 
log
 
to
 
determine
 
the
 
reason
 
for
 
the
 
lit
 
LED
 
(for
 
a
 
VRM).
 
2.
   
Find
 
the
 
failing
 
or
 
missing
 
VRM
 
by
 
checking
 
the
 
LEDs
 
on
 
the
 
system
 
board.
 
3.
   
Install
 
any
 
missing
 
VRMs.
 
4.
   
Reseat
 
the
 
following
 
components:
 
a.
   
Failing
 
VRM
 
b.
   
(Trained
 
service
 
technician
 
only)
 
Microprocessor
 
associated
 
with
 
the
 
VRM
5.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
Failing
 
VRM
 
b.
   
(Trained
 
service
 
technician
 
only)
 
Microprocessor
 
associated
 
with
 
the
 
VRM
 
c.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
 
92
 
IBM
 
System
 
x3500
 
Type
 
7977:
 
Installation
 
Guide