Справочник Пользователя для IBM Type 7977

Скачать
Страница из 124
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
on
 
the
 
IBM
 
System
 
x
 
Documentation
 
CD
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Lit
 
light
 
path
 
diagnostics
 
LED
 
with
 
the
 
system-error
 
or
 
information
 
LED
 
also
 
lit
 
Description
 
Action
 
SERVICE
 
PROCESSOR
 
BUS
 
There
 
is
 
a
 
fault
 
in
 
the
 
Remote
 
Supervisor
 
Adapter
 
II
 
SlimLine.
 
1.
   
Reseat
 
the
 
Remote
 
Supervisor
 
Adapter
 
II
 
SlimLine.
 
2.
   
Update
 
the
 
firmware
 
for
 
the
 
Remote
 
Supervisor
 
Adapter
 
II
 
SlimLine
 
(see
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
on
 
the
 
IBM
 
System
 
x
 
Documentation
 
CD).
 
3.
   
Replace
 
the
 
Remote
 
Supervisor
 
Adapter
 
II
 
SlimLine.
 
MEMORY
 
Memory
 
failure.
 
Note:
 
The
 
error
 
LED
 
on
 
the
 
DIMM
 
is
 
also
 
lit.
 
1.
   
Remove
 
the
 
DIMM
 
that
 
has
 
the
 
lit
 
error
 
LED;
 
then,
 
press
 
the
 
light
 
path
 
diagnostics
 
button
 
on
 
the
 
DIMM
 
to
 
identify
 
the
 
failed
 
DIMM.
 
2.
   
Reseat
 
the
 
DIMM.
 
3.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
DIMM
 
b.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
DASD/RAID
 
A
 
hard
 
disk
 
drive,
 
integrated
 
SAS
 
controller,
 
or
 
integrated
 
RAID
 
error
 
has
 
occurred.
 
Notes:
  
1.
   
The
 
error
 
LED
 
on
 
the
 
failing
 
hard
 
disk
 
drive
 
is
 
also
 
lit.
 
2.
   
Check
 
the
 
BMC
 
event
 
log
 
for
 
a
 
ServeRAID-8k
 
or
 
RAID
 
error.
 
1.
   
Reinstall
 
the
 
removed
 
drive.
 
2.
   
Reseat
 
the
 
following
 
components:
 
a.
   
Failing
 
hard
 
disk
 
drive
 
b.
   
SAS
 
hard
 
disk
 
drive
 
backplane
 
c.
   
SAS
 
signal
 
and
 
power
 
cables
 
d.
   
ServeRAID-8k
 
adapter
3.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
Failing
 
hard
 
disk
 
drive
 
b.
   
SAS
 
hard
 
disk
 
drive
 
backplane
 
c.
   
SAS
 
signal
 
and
 
power
 
cables
 
d.
   
ServeRAID-8k
 
adapter
 
e.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
FAN
 
A
 
fan
 
has
 
failed
 
or
 
has
 
been
 
removed.
 
Note:
 
A
 
failing
 
fan
 
can
 
also
 
cause
 
the
 
TEMP
 
LED
 
to
 
be
 
lit.
 
1.
   
Reinstall
 
the
 
removed
 
fan.
 
2.
   
Reseat
 
the
 
fan.
 
3.
   
If
 
an
 
individual
 
fan
 
LED
 
is
 
lit,
 
replace
 
the
 
fan.
 
4.
   
(Trained
 
service
 
technician
 
only)
 
Replace
 
the
 
system
 
board.
 
 
Chapter
 
5.
 
Solving
 
problems
 
93