3 Controller
  CC-Link interface   
3-124
■ Specifications
Table 3-35 : Specifications
Item
Specifications
Remarks
Communication function
Bit data and word data can be transmitted.
Word data are used by the registers.
Station type
Intelligent device station 
Note1) 
Note1) The CC-Link interface supports neither the transient transmission function nor the FX series.
Support station
Local station
No master station function
The version corresponding to CC-Link
Ver.2
The extended cyclic setup is possible. 
Mountable option slot
Slot 1, 2
Number of mountable CC-Link interface cards
1
Multiple CC-Link interface cards cannot be 
inserted. 
Number of stations
1 to 64 stations
When four stations are occupied, continuous 
station numbers are used. The station 
numbers are set by a DIP switch.
Transmission speed
10M/5M/2.5M/625K/156K bps
This is set by the rotary SW.
Station number
1 to 64 
When two or more stations are occupied, 
continuous station numbers are used.
Number of occupied stations
1/2/3/4
Extended cyclic setup
1/2/4/8
Maximum link point
Remote I/O
 (RX, RY). 
Each 896 points
The two last cannot be used. 
Remote register 
(RWr, RWw) 
Each 128 register
16 bits/register
Extended cyclic setup
-
1 fold 
setup
2 fold 
setup
3 fold 
setup
4 fold 
setup
Link point 
per set
When one 
station is 
occupied
Remote I/O
 (RX, RY). 
32 point
32 point
64 point
128 point
Remote register 
( RWw) 
4 word
8 word
16 word
32 word
Remote register 
(RWr) 
4 word
8 word
16 word
32 word
When two 
stations is 
occupied
Remote I/O
 (RX, RY). 
64 point
96 point
192 point
384 point
Remote register 
( RWw) 
8 word
16 word
32 word
64 word
Remote register 
(RWr) 
8 word
16 word
32 word
64 word
When three 
stations is 
occupied
Remote I/O
 (RX, RY). 
96 point
160 point
320 point
640 point
Remote register 
( RWw) 
12 word
24 word
48 word
96 word
Remote register 
(RWr) 
12 word
24 word
48 word
96 word
When four 
stations is 
occupied
Remote I/O
 (RX, RY). 
128 point 224 point
448 point
896 point
Remote register 
( RWw) 
16 word
32 word
64 word
128 word
Remote register 
(RWr) 
16 word
32 word
64 word
128 word
Number of the maximum occupancy station
4 stations
The I/O first number of the robot controller. 
No. 6000 -.
The number corresponding to the station 
number by the setup of the parameter 
"CCFIX."