Power Safety
Protect 8.33
Industrial High Power UPS
Complete Systems
Protect 8. is a true on-line double conversion UPS classified as 
VFI SS 111 according to IEC 62040-3.
• 
On-line operation ensures permanent service
•  
Microprocessor-driven control and command system 
provides reliable power supply
•  
Battery management system boosts battery life and cuts 
operating costs
•  
Broad range of output power ratings, battery autonomy 
times and options meet complex industrial applications 
needs
•  
High level protection for users and connected equipment 
(high intermittent overload capacity; high level short 
circuit strength)
• 
Excellent dynamic response easily high cyclic loads.
Unique Design
Protect 8. UPS configurations:
• 
Single systems
• 
Parallel systems
• 
Customized input/output voltages
• 
Text translations to any language.
Parallel operation for capacity and performance:
•  
 Flexible Multi Master technology and Can-Bus communi-
cation up to 8 UPS to be connected in parallel for increased 
power, redundancy or system upgrade
•  
Parallel UPS can be operated with separated or central 
battery.
Key Features
High and constant efficiency even at low output power:
• 
Reduced operating costs
• 
Reduced air conditioning requirements
• 
Reduced battery Ah requirments.
Full digital control:
• 
High reliability (no potentiometers)
• 
High flexibility (software controlled parameters)
• 
Fast dynamic response.
Oversized components ensure:
• 
Higher reliability and MTBF
• 
High overload capacity.
Redundant control for high reliability:
•  
Separate microprocessors for rectifier, inverter, static switch 
and communication
•  
Separate, redundant power supplies for control cards.
Low maintenance cost
Ergonomic control unit with graphical display
Input isolation transformer
High short-circuit resistance
High EMC robustness compared to UPS Standard IEC 62040-2
by a factor of 2-to-3
Redundant and individually monitored fans
Floating 384V battery voltage for linking to existing DC bus 
bars (160 - 500kVA)
Intelligent battery management, test and status diagnostics
Compatible with all battery types:
• 
Vented lead acid
•  
Valve regulated lead acid (VRLA)
•  
Nickel cadmium.
Designed to operate with diesel generators
Additional system equipment:
• 
Bypass transformer
•  
Voltage stabilizer
•  
Maintenance bypass switch
•  
AC distribution panels
•  
Battery cubicles
•  
Explosion proof battery circuit breaker enclosures.
Full compatibility with all other AEG Power Solutions:
• 
Industrial DC systems
•  
Telecom systems.