Справочник Пользователя для Pelco C561M-I (4/08)
8
C561M-I (4/08)
Specifications
ELECTRICAL
Input Voltage
Selectable 100, 120, 240 VAC, 50/60 Hz through the Primary Line
Input connector strip
Input connector strip
Output Voltage/Power
Selectable 24 VAC (Tap A), 26 VAC (Tap B), or 28 VAC (Tap C) at
100 VA through the Secondary Output Tap connector strip
100 VA through the Secondary Output Tap connector strip
Fusing
1 fuse. Select from one of the following supplied fuses:
3, 1.6 A fast-acting fuses (120 VAC)
3, 500 mA fast-acting fuses (240 VAC)
3, 1.6 A fast-acting fuses (120 VAC)
3, 500 mA fast-acting fuses (240 VAC)
Spare Fuse Holder
2 spare fuse holders (attached to transformer cover)
Required Input Current
1 A
MECHANICAL
Contruction
Aluminum
Finish
Gray polyester powder coat
Cable Entry
2 hole plugs will accommodate 3/4-inch (1.91 cm) conduit fittings
(not supplied) that meet NEMA Type 4X standards.
(not supplied) that meet NEMA Type 4X standards.
Mount Method
4, 0.375-inch (0.95 cm) holes on mounting plate.
Latch
1 stainless steel link-lock latch secured with screw; latch also can
be secured with padlock (not supplied)
be secured with padlock (not supplied)
GENERAL
Environment
Indoor/outdoor
Operating Range
-50° to 122°F (-45.56° to 50°C)
Weight
6.84 lb (3.10 kg)
(Design and product specifications subject to change without notice.)