Справочник Пользователя для Pelco C561M-I (4/08)

Скачать
Страница из 12
8
C561M-I (4/08)
Specifications
ELECTRICAL
Input Voltage
Selectable 100, 120, 240 VAC, 50/60 Hz through the Primary Line 
Input connector strip
Output Voltage/Power
Selectable 24 VAC (Tap A), 26 VAC (Tap B), or 28 VAC (Tap C) at 
100 VA through the Secondary Output Tap connector strip
Fusing
1 fuse. Select from one of the following supplied fuses:
3, 1.6 A fast-acting fuses (120 VAC)
3, 500 mA fast-acting fuses (240 VAC)
Spare Fuse Holder
2 spare fuse holders (attached to transformer cover)
Required Input Current
1 A
MECHANICAL
Contruction
Aluminum
Finish
Gray polyester powder coat
Cable Entry
2 hole plugs will accommodate 3/4-inch (1.91 cm) conduit fittings 
(not supplied) that meet NEMA Type 4X standards.
Mount Method
4, 0.375-inch (0.95 cm) holes on mounting plate.
Latch
1 stainless steel link-lock latch secured with screw; latch also can 
be secured with padlock (not supplied)
GENERAL
Environment
Indoor/outdoor
Operating Range
-50° to 122°F (-45.56° to 50°C)
Weight
6.84 lb (3.10 kg)