Справочник Пользователя для Micro Technic PV-1800

Скачать
Страница из 19
Users Manual & Installation Guide  
                            PV- 1800: Power supply module with GSM MODEM 
 
 
Page 3 / 19 
General information 
 
Ordering codes 
Model 
number 
Ordering 
code 
Description 
PV-1800-S-1 
016.104.088 
PV-1800-S-2 
016.104.115 
PV-1800-S-3 
016.104.116 
PV-1800-S-4 
016.104.117 
PV-1800-S-5 
016.104.101 
GSM/GPRS modem, digital I/Os, analogue inputs, an RS232 port, and 
20W power supply. 
PV-1800A-S-1  016.104.109 
PV-1800A-S-2  016.104.118 
PV-1800A-S-3  016.104.119 
PV-1800A-S-4  016.104.120 
PV-1800A-S-5  016.104.121 
GSM/GPRS modem, digital I/Os, analogue inputs, and an RS232 port. 
PV-1820-S 
016.104.089 
GSM/GPRS modem, digital I/Os, and 20W power supply. 
PV-1820A-S 
016.104.123 
GSM/GPRS modem and digital I/Os. 
PV-1830-S 
016.104.096 
GSM/GPRS modem and 20W power supply. 
PV-1830A-S 
016.104.106 
GSM/GPRS modem. 
-S = Stack-through PC/104 connector 
 
Analogue configurations 
PV-1800-S and PV-1800A-S are available with different analogue configurations. 
The configuration is indicated by a digit following the model number, e.g. PV-1800-S-1.  It can be: 
 
Digit 
Configuration 
-1 
8AI: AI0-7 = 0-2.5V 
-2 
8AI: AI0-7 = 0-5.0V 
-3 
8AI: AI0-7 = 0-10.0V 
-4 
8AI: AI0-7 = 0-20.0mA 
-5 
8AI: AI0-3 = 0-2.5V, AI4-7 = 0-20mA 
 
Accessories 
These accessories must be ordered separately if needed. 
 
Model no 
Ordering code  Description 
GSM cable 
126.033.000 
RG136 cable with MMCX-SMA MALE 140mm 
GSM Antenna  060.302.001 
GSM antenna with SMA connector 
CM-2 
425.104.001 
Mains cable with one crimp connector mating KL1, 30cm 
CDB-9M 
425.104.002 
Cable with one DSUB9 male and one 10pin IDC-connector, 30cm 
Used for connecting RS232. 
CDB-9F 
425.104.003 
Cable with one DSUB9 female and one 10pin IDC-connector, 30cm 
Used for connecting Ain, Din, Dout and Modem AUX.