Справочник Пользователя для Micro Technic PV-1800

Скачать
Страница из 19
Users Manual & Installation Guide  
                            PV- 1800: Power supply module with GSM MODEM 
 
 
Page 6 / 19 
 
 
 
 
 
 
 
 
Power Supply 
The on-board power supply consists of a synchronous step-down switching regulator with an 
efficiency of 85-95%, depending on input voltage and load current. At nominal input voltage (24V 
DC) and a load current of 2A the efficiency is 92%. A green status LED, placed on the rear side of 
the PCB, is on when the +5V is present. 
 
 
 
 
 
 
 
 
The connector for the power input is a 2 pole pin header from Molex. The mating part for this 
connector is Molex 10-17-3020 with 2 crimp terminals – Molex 2478. 
 
Modem 
The modem unit used in the PV-1800 module is a Sony Ericsson GM47 which is a GSM dual band 
product for 900/1800 MHz. The unit is placed in a 60pin socket and secured by two M2 screws and 
nuts. 
Modem status LED 
A yellow status LED is connected to the modem. This LED is placed on the rear side of the PCB. 
The LED has this function: 
 
 
 
 
Setting up the module 
All communication between the modem and the CPU is done through an on-board 16C550 
compatible UART. The COM port and the IRQ used for the modem are set by two jumper blocks. 
The address is set by one to three jumpers in positions 1 to 3 in section COM_A. 
The table shows how different COM ports can be configured. 
Modem LED
 
Status
 
Off 
Modem off 
On, steady 
Power on, not connected to network 
On, flashing 
Power on, connected to network 
 
)=&6 5> 8*0
 
% 0
$* $