Users Manual & Installation Guide  
                            PV- 5127: 
Power supply module with UPS 
 
 
Page 16 of 31 
RS232 Status signals 
The Battery low and Mains failure signals together can tell three different states: 
 
Mains failure 
Battery low  Status 
Running normally on mains power. 
Mains alarm, running on battery. The CPU is advised to shut down if 
mains power doesn’t come back within reasonable time.  This time 
should be configured in the UPS monitoring software. 
Critical alarm. The CPU is advised to shut down immediately. 
This happens in two situations: 
  During mains failure and the battery is critically low. 
  When the system is 
too hot
RS232 Shutdown signal 
When the CPU activates the Shutdown signal for one second, the PV-5127 immediately turns off 
the +5V and +12V power, and, if mains is not present, also the +5V STB.  Pulses shorter than one 
second have no effect.  For details, please see the section ATX and Softoff state machines
 
/)
.
,