Power supply module with UPS 
 
 
Page 17 of 31 
PC/104 interface 
The PV-5127 has a software interface where the CPU can read status information and perform a  
power-off through the PC/104 bus.  The power-off can be delayed up to 253 seconds, so that the 
UPS monitoring can start the delayed power-off, then start a shutdown of the operating system, and 
the actual power-off happens after the operating system has finished shutting down. 
 
When a delayed power-off has been initiated, the software can later cancel or modify it.  This 
means that the delayed power-off can be used as a software watchdog: If the software e.g. once 
every second starts a power-off specifying a delay of 10 seconds, the system is continuously kept 
on.  If, because of a software error, the refreshing of the delayed power-off stops, the PV-5127 will 
power off the system in 10 seconds.  If mains is present and the system temperature is OK, the PV-
5127 will turn on again two seconds later, ensuring a clean reboot. 
 
This interface is used by the PV-5127 UPS minidriver for Windows 2000/XP.  You only need the 
following information if you want to write your own UPS monitoring or watchdog software. 
 
To the CPU, the PV-5127 appears as a fixed block of eight I/O addresses at 250h-257h.  It doesn’t 
use any memory addresses, IRQs, or DMA channels. 
 
 
 
 
 
 
 
 
 
 
 
 
SIGNATURE (port 250h, read only)
This port always reads as 37h.  Software can read this register to verify the presence of a PV-5127 
adapter. 
 
STATUS (port 251h, read only)0000bmss 
This port contains the following read-only status information bits. 
 
ss (STATUS bit 1-0): System temperature, according to the internal or external system temperature 
sensor. 
ss=00: Too cold 
ss=01: Cool 
ss=10: Warm 
ss=11: Too hot 
 
m (STATUS bit 2): Mains present. 
m=0: Mains voltage not present, running on battery 
m=1: Mains voltage present 
Address 
Read/write  Function 
250h 
read only 
SIGNATURE 
251h 
read only 
STATUS 
252h 
read only 
BAT_STATUS 
253h 
read only 
RS232_STATUS 
254h 
read/write 
SHUTDOWN 
255h 
Reserved 
256h 
Reserved 
257h 
Reserved