Справочник Пользователя для Micro Technic PV-5127

Скачать
Страница из 31
Users Manual & Installation Guide  
                            PV- 5127: 
Power supply module with UPS 
 
 
Page 29 of 31 
KL2 
Connection of mains and battery voltage are made via KL2 as shown in the table: 
 
Connection in KL2 
Function 
Mains+ in 
Mains- in 
Battery- in 
Battery+ in 
 
Connect mains input to pin 1 and 2.  To use a lead-acid backup battery, connect it to pin 3 and 4, 
otherwise leave pin 3 and 4 unconnected.  To use a NiMH (Nickel Metal Hydride) battery for back-
up, a Micronix PV-1075 can be integrated in the PC/104 stack.  In this case, see documentation 
supplied with PV-1075 for connection of mains and battery. 
 
KL3 
Output power can be supplied from connector KL3.  This should be used if the output current 
exceeds the PC/104 connector limits, see section PC/104 connector (CN1), or if you need power for 
devices that are not powered through the PC/104 bus. 
 
Connection number in KL3  Function 
GND 
GND 
+12V out 
+5V out 
+5V out 
 
*
+,
*
*
+,
*
+,
#
$*
+,
-
.
/
/
0
1
2
(
'
#
"-
*
*
34#
*
5
3
!
"
(
6
7
7