Справочник Пользователя для Siemens X-200
Diagnostics over Industrial Ethernet
6.2 Web Based Management (WBM)
6.2.4.3
The "System Restart & Defaults" WBM Menu
System Restart & Defaults
In this screen, there is a button with which you can restart the device and various options for
resetting to the device defaults.
Figure 6-8
"System Restart & Defaults" Dialog
Restart System Button
Click this button to restart the SCALANCE X-200. You must confirm the restart in a dialog
Click this button to restart the SCALANCE X-200. You must confirm the restart in a dialog
box. During a restart, the SCALANCE X-200 is reinitialized, the internal firmware is reloaded,
and the SCALANCE X-200 runs a self-test. The learned entries in the address table are
deleted. You can leave the browser window open while the SCALANCE X-200 restarts.
Restore Memory Defaults Button
Click on this button to restore the factory configuration settings with the exception of the
Restore Memory Defaults Button
Click on this button to restore the factory configuration settings with the exception of the
following parameters:
• IP address
• IP address
• Subnet mask
• Gateway address
• IP address of the default router
• DHCP flag
• System name
• System location
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,
Commissioning Manual, 1,
6-13