Справочник Пользователя для Barco DCS-200

Скачать
Страница из 170
144
DCS-200  •  User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
Parameters:  
-i (input): 1 - 9
-s (saturation): 0 - 150 (Default: 100)
Query Format:  ISAT -i (input) -?
Query Response:  ISAT -i (input) -s (sat) --min 75 --max 125
List Response:  0:"RGB"
1:"SMPTE"
fpbi
Description:  Selects the specified input as the current input to display. This 
command will perform the valid sync check, route the input, recall video if saved 
or acquire source if not saved. Includes the -f (file) parameter option. Also, the 
IMAP will be updated for the input if the file parameter is specified.
Command Format:  ISEL -i (input) -f (file
Parameters:  -i (input): 1 - 9
-f (file): 1 - 64; If specified, updates the File Association menu to reflect 
the selected file number. If not specified, uses the file number specified 
in the ICREC query.
Query Format:  ISEL -?
Query Response:  ISEL -i (input)
fpif`b=
Description:  Input Sync Slice Threshold Adjust.  This command is only valid for 
analog inputs.
Command Format:  ISLICE -i (input) -t (threshold)
Parameters:  -i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog)
-t(threshold): 8 - 256mV; +8 increments (default: 128mV)
Query Format:  ISLICE -i (input) -?
Query Response:  ISLICE -i (input) -t (threshold) --min 8 -- max 256
fpjm=
Description:  Adjust Input Sample mode. This command is only adjustable for 
analog input types. Other input types will provide query information only.
Command Format:  ISMP -i (input) -s (sample mode)
Parameters:
-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog); 1 - 9 for 
query
-s (sample mode): 0 - over sample, 1 - 1:1 sampling (Default: 1:1)
Query Format:  ISMP -i (input) -?
Query Response:  ISMP -i (input) -s (sample mode) --min 0 -- max 1