_K==oÉãçíÉ=`çåíêçä
Remote Commands
List Format:  Each input type has a different list of valid sample modes.
ISMP -i (input) --list
List Response:  0:"OverSample"
1:"1:1"
fpvk`
Description:  Input Sync Type Adjust.  This command is only valid for analog 
input types.
Command Format:  ISYNC  -i (input) -s (sync)
Parameters:  -i (input): 1 - 8 (7 & 8 only if itype is analog)
-s (sync): 0 - auto, 1 - H/V, 2- CSync, 3- SOG (Default: auto)
Query Format:  ISYNC  -i (input) -?
Query Response:  ISYNC  -i (input) -s(sync) --min 0 --max 3
List Format:  ISYNC -i (input) --list
List Response:  0:"AUTO"
1:"H/V"
2:"CSYNC"
3:"SOG"
fqvmb
Description:  Input Type Adjust.  This command is only adjustable for the analog 
inputs. Other inputs will provide query information only.
Command Format:  ITYPE -i (input) -t (type)
Parameters:  
-i (input):  1 - 8 for adjustments (7 & 8 only if itype is analog) ; 1 - 9 for 
query
-t (type): 1-analog, 2-Y/C, 3-CVBS, 4-SDI, 5-DVI, 6-YPbPr
Query Format:  ITYPE -i (input) -?
Query Response:  ITYPE -i (input) -t (type)
List Format:  Each input type has a different list of valid input types.
ITYPE -i (input) --list
List Response:  1:"RGB"
2:"Y/C"
3:"CVBS"
4:"SDI"
5:"DVI"
6:"YPbPr"