Chapter 6
Cajun Campus CLI – Layer 2
80
Cajun P332MF User’s Guide
Set inband vlan Command
Use the
set inband vlan command to set a value for the management vlan
(from 1 to 3071).
The syntax for this command is:
set inband vlan <value>
set inband vlan <value>
Example:
Cajun_P330-N# set inband vlan 1
Management VLAN number set to 1
Cajun_P330-N# set inband vlan 1
Management VLAN number set to 1
Set flowcontrol Command
Use the
set flowcontrol command to set the send/receive mode for flow-
control frames (IEEE 802.3x or Lucent proprietary) for a full duplex port. Each
direction (send or receive) can be configured separately only for Gigabit ports.
Lucent proprietary flow control cannot be configured on Gigabit ports. The
direction (send or receive) can be configured separately only for Gigabit ports.
Lucent proprietary flow control cannot be configured on Gigabit ports. The
set
flowcontrol command cannot be used on Gigabit ports for which
autonegotiation is enabled.
autonegotiation is enabled.
The syntax for this command is:
set flowcontrol {receive|send|all} <mod_num>/<port_num>
{on|off|proprietary}
set flowcontrol {receive|send|all} <mod_num>/<port_num>
{on|off|proprietary}
value
A VLAN number between 1 and 3071.
Field
Description
receive
Controls the receipt of IEEE802.3x flow-control frames on Gigabit
ports only:
• ON indicates that the local port will act upon flow control frames
ports only:
• ON indicates that the local port will act upon flow control frames
received from the far end
• OFF indicates that the local port will discard flow control frames
received from the far end
send
Controls the sending of IEEE802.3x flow-control frames from Gigabit
ports only:
• ON indicates that the local port is allowed to send flow control
ports only:
• ON indicates that the local port is allowed to send flow control
frames to the far end
• OFF indicates that the local port is not allowed to send flow control
frames to the far end