Справочник Пользователя для Lucent Technologies Comcode 108678723

Скачать
Страница из 230
DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration  
555-233-124  
Issue 1
April 2000
Troubleshooting 
6-15
Troubleshooting ATM-CES 
6
— These virtual circuits may persist beyond the duration of a phone 
call. The DEFINITY Call Processing software saves virtual circuits 
for a few seconds after the end stations have hung up in case the 
VC can be used again for another call between the same two port 
networks.
— There may be other CBR virtual circuits between ATM switch ports 
that are not associated with DEFINITY port networks. A common 
CBR application is Circuit Emulation, in which T-1, T-3, and so forth 
circuits are carried over ATM.
Unusual ATM trouble conditions 
A few failure modes in the DEFINITY ECS/ATM switch combination are 
particularly difficult to diagnose. One example might be that you cannot make a 
completely successful call even though most indications from DEFINITY ECS and 
the ATM switch look good. 
This section documents some hints and clues that may help diagnose the 
following failure modes:
Incorrectly typed or omitted EPN route or 
end system identifier (ATM switch)
Symptoms
Talk paths are one-way, from the PPN to the EPN: you can hear tones from the 
PPN end station to the EPN end station but not vice versa. Because the signaling 
channels are bidirectional virtual circuits (VCs) established from the PPN to the 
EPN, these can be routed correctly and come up just fine. Talk paths are two 
unidirectional virtual circuits, so a single call has one VC from the PPN to the EPN 
(which is routed correctly) and one VC from the EPN to the PPN (which cannot be 
routed).
Diagnostics
1. At the ATM switch, check the ATM addresses.
2. Look for a cause code 3 (
No route to destination
).
Action
1. Correct the ATM address translations in the ATM switch.