DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration  
555-233-124  
Issue 1
April 2000
Troubleshooting 
6-17
Troubleshooting ATM-PNC 
6
—Provides guidelines for troubleshooting
—Describes difficult-to-diagnose failure 
modes in the DEFINITY ECS and ATM switch combinations.
Describes the 
following specific troubleshooting commands:
Inspecting LEDs 
To get a high-level status of the system, observe the LEDs on the 
TN2305/TN2306 ATM interface circuit packs and the ATM switch. For information 
on interpreting the LEDs on the ATM switch, refer to your switch’s quick reference 
guide. For information on interpreting the LEDs on the TN2305/TN2306 circuit 
packs, refer to the following book:
DEFINITY Enterprise Communications Server Release 8 Maintenance for 
R8r
Troubleshooting synchronization (400A only)
Connected through an ICSU
To troubleshoot 400A synchronization problems in systems where the 
synchronization signal connects through an ICSU, follow the procedures in 
Table 6-7. Troubleshooting 400A synchronization (through an ICSU) 
Step
Action
Description
1.
Check all connections
If the LEDs on the DS1 circuit pack indicate an error 
condition, or any of the tests associated with testing the 
DS1 circuit pack fails, recheck all cables, connectors, and 
the splitter connection to the back of the DS1 circuit pack.
2.
Test the circuit pack
Test the circuit pack (test board 
UUCSS).
If the tests pass, go to step 14 (release). If a test fails, 
continue with step 3.
Continued on next page