Feeding documents 
that require special 
handling
The gap release lever allows you to manually adjust the space between 
the feed module and separation roller for documents that require 
special handling; i.e. documents that are badly torn. If you are in doubt 
about whether a damaged document can be transported through the 
scanner, use the gap release lever and manually feed the document. 
Using the scanner in continuous feed mode is recommended when 
handling special documents.
1. Press and hold the gap release lever — this provides clearance to 
ease document feeding.
2. Push the document into the elevator tray. If more than one 
document is to be scanned, feed them one at a time.
3. After the document(s) has been fed, release the gap release lever.
Calibrating the 
scanner
There are two types of calibration that can be performed on the i600/
i700 Series Scanners: Image calibration and Ultrasonics calibration. 
• Image calibration: optimizes the optical system in your scanner in 
order to achieve the best overall quality of scanned images. Frequent 
calibration is not needed or recommended.
IMPORTANT: If the White Background Accessory is installed, it must be 
replaced with the black background strip, and the 
scanner must be rebooted prior to calibration.
• Ultrasonics calibration: ensures that the ultrasonics system that 
detects multi-feeds and document edges is properly adjusted for best 
performance. Frequent calibration is not needed or recommended.