Справочник Пользователя для SMART Technologies 880ix3 AND 885ix3

Скачать
Страница из 122
CHAPTER 5
TROUBLESHOOTING THE INTERACTIVE WHITEBOARD SYSTEM
47
smarttech.com/kb/170911
l
If necessary, complete additional troubleshooting with the guidance of SMART Support using
SMART Board Diagnostics.
l
Confirm that the camera system cable is connected to the back of the pen tray.
l
Reset the interactive whiteboard system. If necessary, complete additional troubleshooting
with the guidance of SMART Support using SMART Board Diagnostics.
Resolving connection issues
To resolve connection issues, complete the following tasks:
l
Confirm that the ECP cable harness’s 4-pin power mini-DIN connector is properly connected
to the DC 5V 2A connector on the projector.
l
Confirm that the ECP cable harness’s DB9M RS-232 connector is properly connected to the
Control connector on the projector.
l
Confirm that the USB cable, which is located on the underside of the pen tray, is properly
connected from the interactive whiteboard to the ECP.
l
If necessary, complete additional troubleshooting on any devices between the USB
connection from the computer to the interactive whiteboard system, including any USB hubs
and extension cables.
NOTES
o
If you’re using the CAT 5 USB extender, see
Troubleshooting tips for the CAT 5 USB
extender for SMART Board 800 series interactive whiteboards
(
).
o
Computers connected to the ECP override computers connected to the CAT 5 USB
extender. If you connect two computers to the ECP, any computer connected to the
CAT 5 USB extender doesn’t have a data connection to the interactive whiteboard.
Resolving controller module issues
If the controller module takes longer than 10 seconds to start, disconnect the interactive
whiteboard’s power cable, wait 10 seconds, and then reconnect it.
If the issue persists, update the firmware as documented in the
SMART Board 800 series
interactive whiteboard user’s guide (
).
If the Ready light indicates that a firmware update is in progress but no update is actually taking
place, disconnect the interactive whiteboard’s power cable, wait 10 seconds, and then reconnect
it.