The SD Code column on the Cycle Log shows the Shutdown Code for each cycle. The shutdown code is a 2-digit code 
that gives the reason why the cycle stopped. See a list of the shutdown codes in the table below.
Shutdown 
Code #
Description
0
Normal Completion of Cycle
1
Handheld – Trigger released before cycle was complete
2
Torque High
3
Angle High
4
Yield override failure
5
Prevailing torque seating torque fail
6
Prevailing torque seating angle fail
7
Reserved for future use
8
Forced to shutdown because sync flag was set
9
Reserved for future use
10
Motor stalled (I2t limit reached)
11
User tr is less than the target torque which would cause a stall
12
MCE – IGBT fault
13
MCE – Overcurrent
14
MCE – Low bus voltage
15
Cycle timeout
16
The controller issued a stop command to the tool.
17
The tool was disconnected during cycle
18
MCE – communications lost between MCE and the controller
19
Bad Torque Reference - torque step ref+tare-overshoot is > the step limit
20
MCE – Watchdog timer fired
21
Retorque steps complete without reaching the setpoint
22
When “yield override” is enabled and “fail on yield” is disabled, if the final torque reached is below the 
torque low limit
23
Cycle stopped due to tool becoming disabled
24
Stick slip occurrence
25
Slope A/Gradient high
26
Reserved for future use
27
Slope B high
28
No bolt was found
29
Proximity Switch – normal shutdown 
30
MCE – motor temperature high
31
MCE – drive temperature high
32
Spindle TactAlert – normal shutdown
33
Cycle ended before achieving threshold torque
100
Powerhead – spindle stopped due to command from powerhead master
101
Powerhead – spindle in bypass
102
Powerhead – undetermined prerun error
103
Powerhead – spindle emergency stop activated while in cycle 
104
Powerhead – Trigger Abort – trigger inputs removed before spindle achieved torque threshold 
105
Powerhead – Prerun error – no tool connected
106
Powerhead - Prerun error – invalid tool connnected
107
Powerhead - Prerun error – invalid configuration to run
108
Powerhead – Prerun error – settings error – configuration step counts do not match
109
Powerhead – Prerun error – settings error – synchronization maps do not match
110
Powerhead – Prerun error – settings error – Job IDs do not match
111
Powerhead – Prerun error – spindle emergency stop activated
112
Powerhead – Prerun error – spindle in diagnostics mode
113
Powerhead – Prerun error – spindle not ready to run
114
Powerhead – Prerun error – spindle disabled (master only)
115
Powerhead – Prerun error – cannot lock config to run
116
Powerhead – Prerun error – settings CRC does not match
117
Powerhead – Prerun error – unexpected CRC message
118
Powerhead – MCE calibration failed
119
Powerhead – MCE motor over temperature fault
120
Powerhead – MCE motor heatsink over temperature fault