Справочник Пользователя для Ingersoll-Rand 4581740

Скачать
Страница из 48
04581740_ed2 
31
Shutdown 
Code #
Description
121
Powerhead – MCE step sequence error
122
Powerhead – MCE software fault
123
Powerhead – MCE IGBT fault
124
Powerhead – MCE low bus voltage fault
125
Powerhead – MCE hardware watchdog fault
126
Powerhead – MCE calibration failed due to EEPROM mode
127
Powerhead – MCE calibration failed due to offset
128
Powerhead – MCE calibration failed due to shunt calibration
129
Powerhead – spindle was not known to be stopped at cycle complete
130
Powerhead – timeout on start
131
Powerhead – configurations do not match
132
Powerhead – invalid tool connected
133
Powerhead – no tool connected
134
Powerhead – spindle stopped at a sync point
135
Powerhead – spindle in diagnostics mode
To access and use the Cycle Log:
1.  Press the Stats button on the Insight controller.
2.  On the Statistics menu, select Cycle Log and press Enter.
3.  Scroll through the cycles that have been recorded using the arrow keys.
4.  Move the cursor to the C (Clear) button and press Enter to clear all existing cycle data.
 
NOTE: Although using the C button clears data on up to 1,000 cycles, it does not reset the counter. The counter 
continues up to 9,999, unless reset with the ICS Software.
Screen Element
Description
Clear Cycle Data This button will clear the cycle log data table for the displayed spindle.
Main Window
This window displays the cycle log summary table. Additional information on the parameters 
displayed is described below.
5.1.2  Spindle Statistics
The Spindle Statistics screen displays useful statistics that have been calculated from the data collected. Note that on 
the left side of the screen displays the statistical data for all the fastenings performed since the statistics were last reset 
(the Population Stats), while the right side the statistics for a subset of the cycle (the Sample Stats) The sample size for 
Sample Stats is set to 25 by default, but this parameter may be changed in the Stats Settings screen. Both Population 
and Sample statistics may also be reset on that screen.
Figure 27 - Spindle Statistics
Note that you must use the dropdown box to select the Configuration from which you wish to view the spindle 
statistics. These statistics are only available for the first eight Configurations. The ICS Software can be set up to calculate 
statistics for further Configurations.
To access and use the Spindle Statistics:
1.  Press the Stats button on the Insight controller.